ToggleINTRODUCTION
ChronoSync does not directly support the automatic log out of your Mac after running a sync. Use this document to create a post-synchronization AppleScript that will log out from the Mac upon completion of the sync document.
RESOLUTION
Use the following steps to create the post-sync AppleScript to log out of your Mac. This procedure makes use of the AppleScript Editor which be found in the Applications->Utilities folder.
Open the AppleScript Editor
Open the Utilities folder, found in the Applications folder of your Mac, then open the AppleScript Editor.
Create the AppleScript
Copy the following script and paste it into the AppleScript Editor:
tell application “System Events”
log out
end tell
set quitResult to do shell script “ps axjww”
if quitResult contains “Applications/ChronoSync” then
do shell script “killall ChronoSync”
delay 2
end if
Compile and Test
Click the ‘Compile’ button in the AppleScript Editor toolbar. Check for any errors. Now, test the script. Remember, if everything works, the Mac log out! Now click the ‘Run’ toolbar button. Does the Mac log out? Correct any errors before continuing.
Save the AppleScript
Save the AppleScript by going to the menubar and choosing File -> Save. Make sure to choose the ‘Script’ File Format if it is not chosen already. Choose a directory to store the AppleScript, then choose ‘Save’. It may be helpful to keep any scripts in the same folder where the sync document is stored.
Set the Script in your Sync Task
Open the saved sync document and switch to the Options Panel. Expand the ‘Scripts’ section.
Enable ‘Post-Synchronization script’, then click the ‘Choose’ button and select the AppleScript just created.
Choose whether or not to abort the sync run if the AppleScript encounters an error by enabling or disabling ‘Abort on Script Errors’.
Test the script by clicking ‘Run’.
CONCLUSION
If all has gone well, the AppleScript should log out of your Mac after running the sync.
REVISION HISTORY
Mar-21-2014 – Created from Internal Support Notes.